<ruby id="9evva"><bdo id="9evva"></bdo></ruby>

  • <tbody id="9evva"><p id="9evva"></p></tbody>

    BAODING JIKAI POWER EQUIPMENT CO., LTD.

    Railway Insulator

    Railway Insulator

    Views:

    Principal characteristic:

    Silicone rubber composite insulator as the porcelain insulator’s replacement product, can improve sewage Lightning pressure, reduce the line operation and maintenance workload and blackout time to a bare minimum, improve power supply reliability, and its main features as following:

    1. Tolerance performance to be outstanding.The sewage Lightning pressure is two to three times of porcelain insulator’s. So this product is particularly applicable in the polluted area.

    2. Without cleaning maintenance. Silicon rubber material unique to the migration of water-repellent, making the insulator still with excellent insulator hydrophobic and high pollution lightning pressure after polluting, particularly applicable to the lines where the operation and maintenance are so difficult.

    3. Need no to check zero value.

    4. The weight is light.It is just 1/7-1/10 of the porcelain insulation substring, it is very convenient to transport and install. Therefore, it is particularly applicable to the area where the transportation condition is difficult and faulty line‘s fast emergency repair.

    5. The elasticity is good, not brittle. The silicon rubber material still has the good elasticity, even in - 60℃, therefore, this product nearly doesn’t exist the problem of breakage durning transporting and installing.


    Product model signification:





    Tilted single insulating bracket support composite insulator


    Level single insulating bracket support composite insulator

     
    NO. Model Rating voltage
    (kV)
    Rated load damage
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    Power frequency minute wet
    withstand voltage
    kV
    Tensile failure Bending failure Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    Dry Wet
    1 FQB-25/8 25 80 8 760 490 1200 270 160 130
    2 FQB-25/12 25 100 12 760 490 1200 290 160 130
    3 FQB-25/16 25 120 16 800 490 1200 310 160 130
    4 FQBJ-25/8 25 80 8 760 490 1400 270 175 140
    5 FQBJ-25/12 25 100 12 760 490 1400 290 175 140
    6 FQBJ-25/16 25 120 16 800 490 1400 310 175 140
    7 FQBG-25/8 25 80 8 800 520 1600 270 190 150
    8 FQBG-25/12 25 100 12 800 520 1600 290 190 150
    9 FQBG-25/16 25 120 16 800 520 1600 310 190 150
     




    Tilted double insulating bracket support composite insulator


    Level double insulating bracket support composite insulator

     
    NO. Model Rating voltage
    (kV)
    Rated load damage
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    Power frequency minute wet
    withstand voltage
    kV
    Tensile failure Bending failure Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    Dry Wet
    1 FQBS-25/8 25 80 8 760 490 1200/145 270 160 130
    2 FQBS-25/12 25 100 12 760 490 1200/145 290 160 130
    3 FQBS-25/16 25 120 16 800 490 1200/145 310 160 130
    4 FQBSJ-25/8 25 80 8 760 490 1400/145 270 175 140
    5 FQBSJ-25/12 25 100 12 760 490 1400/145 290 175 140
    6 FQBSJ-25/16 25 120 16 800 490 1400/145 310 175 140
    7 FQBSG-25/8 25 80 8 800 520 1600/145 270 190 150
    8 FQBSG-25/12 25 100 12 800 520 1600/145 290 190 150
    9 FQBSG-25/16 25 120 16 800 520 1600/145 310 190 150
     



    25kV single insulating suspension composite insulator
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H mm Creepage distance H
    mm
    1 FQX-25/100QT 25 80 700±20 500 1200 270 130
    2 FQX-25/120QT 25 120 700±20 500 1200 270 130
    3 FQX-25/160QT 25 160 750±20 500 1200 270 130
    4 FQX-25/100QTJ 25 80 750±20 550 1400 290 140
    5 FQX-25/120QTJ 25 120 750±20 550 1400 290 140
    6 FQX-25/160QTJ 25 160 800±20 550 1400 290 140
    7 FQX-25/100QTG 25 80 800±20 600 1600 310 160
    8 FQX-25/120QTG 25 120 800±20 600 1600 310 160
    9 FQX-25/160QTG 25 160 850±20 600 1600 310 160
     




    25kV double insulating suspension composite insulator

     
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H mm Creepage distance H
    mm
    1 FQX-25/100QT 25 80 790±20 500 1200/145 270 130
    2 FQX-25/120QT 25 120 790±20 500 1200/145 270 130
    3 FQX-25/160QT 25 160 840±20 500 1200/145 270 130
    4 FQX-25/100QTJ 25 80 840±20 550 1400/145 290 140
    5 FQX-25/120QTJ 25 120 840±20 550 1400/145 290 140
    6 FQX-25/160QTJ 25 160 890±20 550 1400/145 290 140
    7 FQX-25/100QTG 25 80 890±20 600 1600/145 310 160
    8 FQX-25/120QTG 25 120 890±20 600 1600/145 310 160
    9 FQX-25/160QTG 25 160 940±20 600 1600/145 310 160
     




    25kV single insulating suspension composite insulator

     
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    1 FQX-25/100QT 25 80 700±20 500 1200 270 130
    2 FQX-25/120QT 25 120 700±20 500 1200 270 130
    3 FQX-25/160QT 25 160 750±20 500 1200 270 130
    4 FQX-25/100QTJ 25 80 750±20 550 1400 290 140
    5 FQX-25/120QTJ 25 120 750±20 550 1400 290 140
    6 FQX-25/160QTJ 25 160 800±20 550 1400 290 140
    7 FQX-25/100QTG 25 80 800±20 600 1600 310 160
    8 FQX-25/120QTG 25 120 800±20 600 1600 310 160
    9 FQX-25/160QTG 25 160 850±20 600 1600 310 160
     




    25kV double insulating suspension composite insulator

     
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    1 FQX-25/100QT 25 80 790±20 500 1200/145 270 130
    2 FQX-25/120QT 25 120 790±20 500 1200/145 270 130
    3 FQX-25/160QT 25 160 840±20 500 1200/145 270 130
    4 FQX-25/100QTJ 25 80 840±20 550 1400/145 290 140
    5 FQX-25/120QTJ 25 120 840±20 550 1400/145 290 140
    6 FQX-25/160QTJ 25 160 890±20 550 1400/145 290 140
    7 FQX-25/100QTG 25 80 890±20 600 1600/145 310 160
    8 FQX-25/120QTG 25 120 890±20 600 1600/145 310 160
    9 FQX-25/160QTG 25 160 940±20 600 1600/145 310 160
     




    25kV single insulating suspension composite insulator
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency
    wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    1 FQX-25/100HH 25 80 700±20 500 1200 270 130
    2 FQX-25/120HH 25 120 700±20 500 1200 270 130
    3 FQX-25/160HH 25 160 750±20 500 1200 270 130
    4 FQX-25/100HHJ 25 80 750±20 550 1400 290 140
    5 FQX-25/120HHJ 25 120 750±20 550 1400 290 140
    6 FQX-25/160HHJ 25 160 800±20 550 1400 290 140
    7 FQX-25/100HHG 25 80 800±20 600 1600 310 160
    8 FQX-25/120HHG 25 120 800±20 600 1600 310 160
    9 FQX-25/160HHG 25 160 850±20 600 1600 310 160
     




    25kV double insulating suspension composite insulator

     
    NO. Model Rating
    voltage
    (kV)
    Rated mechanical bending
    load
    kN
    Main dimensions Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     
    1min
    Power frequency wet withstand voltage
    kV
    Structure height H
    mm
    Minimum arc distance H
    mm
    Creepage distance H
    mm
    1 FQX-25/100HH 25 80 790±20 500 1200/145 270 130
    2 FQX-25/120HH 25 120 790±20 500 1200/145 270 130
    3 FQX-25/160HH 25 160 840±20 500 1200/145 270 130
    4 FQX-25/100HHJ 25 80 840±20 550 1400/145 290 140
    5 FQX-25/120HHJ 25 120 840±20 550 1400/145 290 140
    6 FQX-25/160HHJ 25 160 890±20 550 1400/145 290 140
    7 FQX-25/100HHG 25 80 890±20 600 1600/145 310 160
    8 FQX-25/120HHG 25 120 890±20 600 1600/145 310 160
    9 FQX-25/160HHG 25 160 940±20 600 1600/145 310 160
     


    Fig.1  Vehicle roof support composite insulator
    Fig.2  Railway switch post composite insulator

    NO. Model Rating
    voltage
    (kV)
    Structure
    height H
    mm

    Minimum
    arc distance
    H
    mm

    Creepage
    distance h
    mm

    Full lightning
    impulse withst
    and voltage
    (the peak
    Value)
    >=
    (kV)
     

    Power
    frequency
    minute
    wet
    withstand
    voltage
    kV
    Dry Wet
    Fig.1 DG-l/400 5 400 290 1050 180 90 80
    Fig.2 FZS-27.5/8 8 600 500 1400 230 110 95
     